Scanner Configuration Manager
Bar Code Symbologies
Modify the output characteristics of 16 of the most popular bar code
symbologies in current use. Following are the bar code symbolo-
gies and their modifiable parameters.
Code 39
Maximum Length defines the maximum length the user will
accept for a valid bar code. Default is “48”.
Minimum Length defines the minimum length the user will
accept for a valid bar code. Default is “0”.
Send Start/Stop toggles sending or not sending start/stop
sentinels (* in the case of Code 39). Default is “No Send”.
Check Digit defines whether or not a check digit (to insure data
accuracy) is calculated, and if so, whether it should be sent or
not. Default is “Not Calculate”.
Type toggles Code 39 between Standard and Full ASCII.
Default is “Full ASCII”.
Code ID (Full ASCII) is the same as Code ID (Standard), above,
except that the symbology is Full ASCII Code 39.
Default letter is also the letter “M”.
Code ID (Standard) is a user-definable identification letter for
Standard Code 39, which is referred to in the “Use Code ID”
function (see page 9). Default is letter “M”.
Enabled toggles the ability for the keyboard/scanner to read
Code 39 on or off. Default is “Yes”.