Unitech MS920 Uživatelský manuál Strana 91

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 118
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 90
- 85 -
- Pulse
- Autostand
- Toggle*
NOTE*: In Toggle trigger mode, "one pull aim, one pull read" does not work as
stated. Instead one pull turns on the aimer only. When the trigger is
released decoding begins. If no decode, second pull turns aimer and
decoding off.
Typical aimer (*)
One pull aim and read
- Pull and hold trigger - aiming beam (programmable duration) then reading
beam.
One pull aim and read
One pull aim, second pull read
- First pull aiming beam, second pull reading beam.
NOTE*: In Toggle trigger mode, "one pull aim, one pull read" does not work as
stated. Instead one pull turns on the aimer only. When the trigger is
released decoding begins. If no decode, second pull turns aimer and
decoding off.
One pull aim, second pull read
Duration
- Duration is applied differently depending on the aiming beam mode:
- First pull aim and read:
- Duration is the time the aiming beam stays on before reading begins
- First pull aim, second pull read:
- Duration is the maximum time between the rst pull and second pull